Auto transformer

  1. Autotransformer: What is it? (Definition, Theory & Diagram)
  2. Autotransformers
  3. Constructing and Operating an Autotransformer
  4. What is Auto Transformer? Advantages & Application


Download: Auto transformer
Size: 55.17 MB

Autotransformer: What is it? (Definition, Theory & Diagram)

What is an Autotransformer? An autotransformer (or auto transformer) is a type of Autotransformer Theory In an auto transformer, one single winding is used as primary winding as well as secondary winding. But in two windings transformer two different windings are used for primary and secondary purpose. A circuit diagram of auto transformer is shown below. The winding AB of total turns N 1 is considered as primary winding. This winding is tapped from point ′C′ and the portion BC is considered as secondary. Let’s assume the number of turns in between points ′B′ and ′C′ is N 2. If V 1 Hence, the voltage across the portion BC of the winding, will be, As BC portion of the winding is considered as secondary, it can easily be understood that value of constant ′k′ is nothing but auto transformer. When load is connected between secondary terminals i.e.between ′B′ and ′C′, load current I 2 starts flowing. The 2 and I 1. Copper Savings in Auto Transformer Now we will discuss the savings of copper in auto transformer compared to conventional two winding transformer. We know that weight of copper of any winding depends upon its length and cross-sectional area. Again length of conductor in winding is proportional to its number of turns and cross-sectional area varies with rated current. So weight of copper in winding is directly proportional to product of number of turns and rated current of the winding. Therefore, weight of copper in the section AC proportional to, and similarly, weigh...

Autotransformers

Substation autotransformers transfer the incoming high voltage to the next lower voltage level. As an example, incoming high voltage of 400 kV would be transferred down to 220 kV. In general substation autotransformers are equipped with on-load tap-changers (OLTC). Incoming transmission lines are connected to the transformers through bushings and cables through cable boxes and cable sealing ends. Autotransformers are built in core form with auto connected windings, ie common main winding and a separate low voltage winding. • Our track record of 1,400+ units delivered since 1995 • Short-circuit performance at twice the industry standard • Proven track record in meeting customer performance requirements (ask forour test floor failure statistics) • 12 factories, one global approach – bringing consistency, delivery performance and technology

Constructing and Operating an Autotransformer

The power rating of an autotransformer is higher than that of an equivalent Operation Transformers typically contain two independent circuits. This includes a primary winding that receives the energy from the source, and a secondary winding that delivers the energy to the load. An autotransformer is a transformer in which the primary and secondary circuits have a portion of their two windings in common. The power rating of an autotransformer is higher than that of an equivalent two-winding transformer. Construction An autotransformer is usually constructed from a single winding with multiple taps. For a step-down application, the source is applied across the entire coil, which acts as the primary. The load is connected across a portion of the whole winding as shown in the figure. The portion connected to the load acts as the secondary. Figure 1.This autotransformer steps the voltage upwith a single copper-saving tapped winding. Image courtesy of The generated electromagnetic field cuts through the entire winding. Therefore, the induced counter voltage is across the entire coil, and the design volts per turn is obtained across each turn of the entire coil. The voltage available to the load is less than the source voltage because there are fewer turns available to the secondary than the primary. Note According to the NEC®, Article 411, Lighting Systems Operating at 30 Volts or Less, a secondary circuit shall be insulated from the branch circuit by an isolating transformer. A...

Autotransformers

HPS offers three phase autotransformers for applications where voltage isolation is not necessary, but some level of voltage adjustment is required. They are frequently used as an economical alternative to three phase general purpose distribution transformers to adjust the supply voltage to match specific load requirements when load isolation from the supply line is not required. Autotransformers can be used as either a step-up or step-down transformer.

What is Auto Transformer? Advantages & Application

What Is Auto Transformer? An Auto Transformer is a laminated core transformer with only one winding wrapped on it. An autotransformer is similar to a two-winding transformer, but the primary and secondary windings are not connected in the same way. Both the major and secondary sides share a portion of the winding. When the load is on, a portion of the load current is taken directly from the supply, while the remainder is obtained by transformer action. A voltage regulator is an autotransformer. What is Auto Transformer? Explanation of Auto Transformer with Circuit Diagram In a conventional Ordinary Two Winding Transformer (Reference: circuitglobe.com) Based on the structure, there are two types of auto transformers. There is continuous winding in one sort of transformer, with taps pulled out at opportune locations specified by the required secondary voltage. Another sort of auto transformer, on the other hand, has two or more separate coils that are electrically coupled to make a continuous winding. The Autotransformer’s construction is depicted in the diagram below. Auto Transformer Circuit Diagram (Reference: circuitglobe.com) The main winding AB is used to tap at C, resulting in CB acting as a secondary winding. The load is linked across CB, while the supply voltage is applied across AB. The tapping might be either constant or varied. When an alternating flux is created in the core by applying an AC voltage V1 across AB, an EMF E1 is induced in the winding AB. The secon...